Home
CompanyProductsForumServiceDownload
 
 
FLE 10: Ferrolux Line Tracing Reiceiver
Current events

Current exibitions

Current seminars




SebaKMT News

Sebalog D

The Sebalog D data logger was specially designed for the requirements of water supply companies and...


VLF 80

We have expanded our product range for the modern semiconductor VLF system with an 80 kV version.


vCam Firmware

You can now download the vCam Digital firmware from the website in the "CCTV inspection" product...


VIVAX vLocPro location system

The VIVAX vLocPro location system has been completely revised and equipped with new features.



Newsletter
Contact
Complaints
Impressum
Sitemap
SebaKMT
Contact: sales@sebakmt.com
Tel: +49 (0)9544-680
Fax: +49 (0)9544-2273

24 hotline
+49 (0) 1805 / 73 22 568
+49 (0)1805/ sebakmt
service@sebakmt.com
DescriptionTechnical DataPicturesLeafletSend Request



SignalSelect:

SignalSelect is a patent technique for identifying the direction of signal flow in a line. This technique clearly enhances the reliability and efficiency of route position finding.

It has its particular merits in all events where there are a number of systems on the site running closely side by side.

 

The generator system FLG 10 generates an especially modulated audio frequency signal which is transmitted into the line either directly or inductively. The receiver system FLE 10 / FS 10 detects this signal over the target line and determines the direction of the signal flow.

 

SuperMax:

The maximum technique used so far has only a very broad resolution. Therefore, it has mostly been used for tasks in the field of ground survey.

 

The new FERROLUX Receiver System FLE 10 / FS 10 features a new level of the maximum technique called SuperMax. Therefore the common maximum (peak) and minimum (null) methods are linked in a special manner.

 

This technique allows even users with little experience to obtain precise results in line locating.

 

DirectSignal:

The analog receiver signal is directly made audible by the internal speaker or earphones. Listening directly to the receiver signal gives the user more information, supports visual indications on the receiver and so increases the efficiency of line locating.

 

Separate rotary controls for signal gain and volume.

Distance-dependant right/left control

 

The direction arrows on the display indicate whether the route position sensor FS10 has to be moved to the left or the right for the target line to be directly underneath the sensor. The changing length of the arrows indicates the distance to the line path.

 

Vertical markings on the arrow appear when the sensor FS10 has reached a 45° angle to the side of the target line.

 

Features

  • Clear display
    Signal flow from the generator to the far end
    Signal flow from the far end to the generator
  • No dependence on line length
  • For any type of line (cable, pipe)
  • Inductive or direct coupling of signal
  • Maximum Method
    Advantage: Best reception above line
    Drawback: Wide locating area
  • Minimum Method
    Advantage: Precise locating
    Drawback: Strong signal to the left and to the right of the line
  • SuperMax Method
    Precise locating with best signal exactly above the line
  • No signal beside the line
  • Highly sensitive coils for signal detection Filtering and optimisation of audio volume Direct output of the analog receiver signal
  • Clearly visible direction readout
  • Distance dependant display of direction
  • Definate indication when receiver is above cable

 

Accessories:

 


Cable and Pipe Line LocatingPrintversionTop