Home
CompanyProductsForumServiceDownload
 
 
BT 500 IS-1
Current events

Current exibitions

Current seminars




SebaKMT News

VIP visit to SebaKMT in Baunach

On 27th August 2008, Eberhard Sinner, the Head of the State Chancellery in Bavaria visited SebaKMT...


GET Nord

SebaKMT will be exhibiting at GET Nord in Hamburg, which is the first combined trade fair for...


vCam Firmware

You can now download the vCam Digital firmware from the website in the "CCTV inspection" product...


VLF 80

We have expanded our product range for the modern semiconductor VLF system with an 80 kV version.



Newsletter
Contact
Complaints
Impressum
Sitemap
SebaKMT
Contact: sales@sebakmt.com
Tel: +49 (0)9544-680
Fax: +49 (0)9544-2273

24 hotline
+49 (0) 1805 / 73 22 568
+49 (0)1805/ sebakmt
service@sebakmt.com
DescriptionTechnical DataPicturesLeafletSend Request


The BT 500-IS-1 Cable Fault Converter is mainly used for converting high-resistive cable faults in signal, control and telecommunication cables into low-resistive ones.

Its source of adjustable voltage 0 to 2 kV has a balanced output, i. e. a faulty pair of wires can be connected to its output terminal balanced to earth (ungrounded).

 

In conjunction with a special Sheath Prelocating Device of type MVG 5, sheath faults can be pre-located. Using this accessory device, the following measurements can be taken:

Sheath fault prelocation on shielded telecommunication and control cables with PVC or PE-type sheath.
Sheath fault prelocation on shielded medium-high voltage cables with PVC sheath (test voltage up to 2kV )

 

Pin pointing is carried out by means of the Earth Fault Locating Device ESG 80-2 by the method of measuring the step voltage. Moreover our new Cable Fault Converter BT 500-IS-1 has some more special features such as:

 

continuously adjustable output voltage in voltage ranges 500, 1000, 2000 V
floating Potential at either outputs
protection against overload by voltage and current control
fault location at reduced power to prevent damages to adjacent wires or cables
indication of voltage and current by two analog indicating instruments
automatic discharge unit provides for removal of residual charge and for earthing the test object
clock-controlled operation of the voltage source to prevent the drying-out of faults when pin pointing sheath faults

 

Accessory equipment:

Earth Fault Locating Device ESG 80-2
Earth spikes with measuring leads EEB
Sheath Fault Prelocating Device MVG 5
Emergency-off switch NAG 1 for stand-alone operation
Emergency-off switch NAG 2 for operation with MVG 5
 


Fault ConverterPrintversionTop